Ind Hole No Volumes  Inductance of a small hole

The IndHoleNoVolume component describes the inductance of an oil column in a small, sharp-edged hole and includes the observed increase compared with the theoretical value. The model is valid for sharp-edged holes with:

0.5 mm < d < 1

and

1 < d / &ell; < 2

There is a check to determine whether the following condition is met:

&ell; > d

Use the modifier

q(start=1e-6,fixed=true)

to set the initial condition for the flow rate of the inductance [m3/s].

 

Equations

Variables

Connections

Parameters

Equations

msim/ALGORITHMmsim/WHEN0<qandpAabs<pvapouroilorq<0andpBabs<pvapouroil&comma;reinitq&comma;0&comma;assertd<&comma;Length of hole must be GREATER than diameter.

ν&equals;Modelica.Media.Air.MoistAir.Utilities.spliceFunctionx&equals;&Delta;p&comma;pos&equals;νoilp&equals;pAabs&comma;T&equals;T&comma;vair&equals;vgasoil&comma;psat&equals;psat&comma;neg&equals;νoilp&equals;pBabs&comma;T&equals;T&comma;vair&equals;vgasoil&comma;psat&equals;psat&comma;&Delta;x&equals;100

ρ&equals;Modelica.Media.Air.MoistAir.Utilities.spliceFunctionx&equals;&Delta;p&comma;pos&equals;ρoilp&equals;pAabs&comma;T&equals;T&comma;vair&equals;vgasoil&comma;psat&equals;psat&comma;neg&equals;ρoilp&equals;pBabs&comma;T&equals;T&comma;vair&equals;vgasoil&comma;psat&equals;psat&comma;&Delta;x&equals;100

T&equals;T0oil&plus;&Delta;Tsystem

leff&equals;4ρ7750&plus;5&ExponentialE;ddd2π

q&equals;mflowAρ

&Delta;p&equals;pAlimitedpBlimited

pAabs&equals;pA&plus;patmoil

pAlimited&equals;maxpA&comma;pvapouroilpatmoil

pBabs&equals;pB&plus;patmoil

pBlimited&equals;maxpB&comma;pvapouroilpatmoil

mflowA&plus;mflowB&equals;0

tq&equals;&Delta;pleff

Variables

Name

Value

Units

Description

Modelica ID

&Delta;p

 

Pa

Pressure drop

dp

q

 

m3s

Flow rate flowing into port_A

q

pAlimited

 

Pa

Limited gauge pressure

pA_limited

pBlimited

 

Pa

Limited gauge pressure

pB_limited

ρ

 

kgm3

Upstream density

rho

ν

 

m2s

Upstream kinematic viscosity

nu

pAabs

 

Pa

Absolute pressure pA

pA_abs

pBabs

 

Pa

Absolute pressure pB

pB_abs

T

 

K

Local temperature

T

pAsummary

pA

Pa

Pressure at port A

summary_pA

pBsummary

pB

Pa

Pressure at port B

summary_pB

&Delta;psummary

&Delta;p

Pa

Pressure drop

summary_dp

qsummary

q

m3s

Flow rate flowing into port_A

summary_q

Phydsummary

&Delta;pq

W

Hydraulic Power

summary_HP

psat

[1]

Pa

Gas saturation pressure

p_sat

leff

 

 

 

leff

[1] oil.gasSaturationPressureT&equals;T&comma;vgas&equals;oil.vgas

Connections

Name

Description

Modelica ID

portA

Layout of port where oil flows into an element (0<mflow, pB<pA means 0<&Delta;p)

port_A

portB

Hydraulic port where oil leaves the component (mflow<0, pB<pA means 0<&Delta;p)

port_B

oil

 

oil

Parameters

Name

Default

Units

Description

Modelica ID

&Delta;Tsystem

0

K

Temperature offset from system temperature

dT_system

0.015

m

Hole length

length

d

8.5·10-4

m

Hole diameter

diameter

See Also